What 40t6 34ng 400 tells you about your water heater

40t6 34ng 400 appears in parts listings for the Whirlpool 40T6-34NG-400. Whirlpool lists the base model as 40T6-34NG: a tall, 40-gallon natural gas water heater with a 34,000 BTU-per-hour input and a six-year warranty.

Before buying a part, check the full model number on your heater’s label. Pilot assembly 100112330 is listed as compatible with the 40T6-34NG-400, but you should also match the original part and confirm the fit. If the heater has stopped working, a qualified professional can check the pilot, gas connections, and venting safely.

Quick guide to identifying the Whirlpool 40T6-34NG-400, checking pilot parts, and finding support infographic

40t6 34ng 400 terms at a glance:

What 40t6 34ng 400 Means in Whirlpool Listings

How to identify the 40t6 34ng 400 model

When searching for replacement parts or maintenance manuals, you may notice that retail platforms and parts suppliers format model numbers differently than the rating plate on the tank. The base unit is categorized as the Whirlpool 40T6-34NG, while parts catalogs frequently append a series code, resulting in the searchable string 40T6-34NG-400.

To verify your equipment, locate the data rating plate affixed to the side of the water tank jacket. This label lists essential factory information:

  • Base Model: 40T6-34NG
  • Listing and Series Suffix: 40T6-34NG-400
  • UPC Code: 035505155450
  • Fuel Type: Natural Gas (NG)
  • Tank Orientation: Tall profile design

Checking the data label directly ensures that you do not order parts meant for standard short tanks or liquid propane configurations. For additional verification, consult the Whirlpool water heater model and support listings to cross-reference series updates and product manuals.

40t6 34ng 400 specifications and warranty at a glance

The 40T6-34NG series was engineered to meet standard residential hot water demands. Sized nominally at 40 gallons, it delivers balanced performance for households of up to three people. It features standard Category I atmospheric draft venting and is certified for operation across a wide elevation spectrum, from sea level up to 10,100 feet.

Specification Feature Factory Detail
Nominal Tank Capacity 40 Gallons
Fuel Configuration Natural Gas
Heat Input Rating 34,000 BTU per hour
Tank Profile Tall
Unit Dry Weight 113 Pounds
Altitude Operational Certification 0 to 10,100 Feet
Factory Limited Warranty 6-Year Tank and Parts

The factory limited warranty covers the inner storage tank and component parts against manufacturing defects for six years. Knowing these specifications helps determine whether replacement parts match the mechanical capacity of your unit.

How the 40T6-34NG Performs and What It Costs

Price, customer rating, and review context

The Whirlpool 40T6-34NG natural gas water heater has established a solid track record in residential settings, earning an average customer rating of 4.4 out of 5 stars across more than 430 verified user reviews. Homeowners consistently highlight its steady hot water delivery and dependable operation.

When evaluating historical product entries, such as the Whirlpool 40-gallon tall natural gas water heater listing, keep in mind that older retail pricing and archive listings reflect past market conditions. When planning a repair or replacement, consider the complete project scope. Total investment includes not just the hardware or pilot component, but also shipping, supply lines, local permit compliance, and professional installation.

Controls, ignition, and built-in safety features

The unit incorporates Whirlpool 6th Sense electronic gas control technology. Rather than relying entirely on manual adjustments, the combination gas valve and thermostat monitors water temperature with electronic precision and provides self-diagnostic status indicators. A flashing LED code on the gas valve face helps homeowners and technicians diagnose issues like thermal sensor faults or supply interruptions without guesswork.

Key mechanical and safety components include:

  • Integrated push-button piezo igniter that lights the pilot without matches
  • Sealed combustion chamber with a glass viewport for visual flame verification
  • Flammable Vapor Ignition Resistance (FVIR) system designed to prevent external vapors from igniting inside the burner chamber
  • Factory-installed temperature and pressure (T&P) relief valve to protect against excessive pressure buildup
  • Modern electronic control architecture without wireless or Bluetooth connectivity

Gas control valve and pilot viewing port assembly

Which Pilot Assembly Fits 40t6 34ng 400?

40t6 34ng 400 pilot assembly part numbers

The most common maintenance requirement for aging atmospheric gas water heaters involves the pilot assembly and thermopile system. If your pilot light will not stay lit after releasing the control knob, the thermopile generator may no longer produce the required millivoltage to hold the internal gas safety magnet open.

The primary replacement pilot assembly for the 40T6-34NG-400 is part number 100112330.

When searching parts networks, this component cross-references several factory and legacy numbers:

  • OEM Part Number: 100112330
  • Superseded Part Numbers: 9007876 and 9007877
  • Related Variant Assemblies: 100112328

These assemblies are designed for natural gas units within the 300 and 301 manufacturing series. They include the pilot tube with ferrule fitting, an integrated 750-millivolt thermopile, an igniter electrode with high-temperature wire, and the heavy-gauge mounting bracket. Always verify your existing assembly’s shape and wiring connectors against the replacement kit before ordering.

Replacement options, prices, and ratings

Replacement pilot and thermopile assemblies are available through various parts channels, ranging from original equipment components to third-party aftermarket alternatives. Across different retailers and marketplaces, listings reflect varying customer feedback scores, review sample sizes, and warranty terms.

Part Reference Component Description Compatibility Scope Market Feedback Summary
100112330 Full Pilot and Thermopile Assembly Whirlpool, American, AO Smith (300/301 Series) High volume reviews; 4.2 to 4.8 star average ratings
9007876 Legacy Factory Pilot Assembly 40T6-34NG-400, 40S6-40NG, 50T6-40NG Superseded by 100112330; highly reliable baseline
9007877 Legacy Pilot Assembly Variant Standard atmospheric natural gas models Superseded by 100112330; verified factory fit
100112328 Cross-reference Thermopile Kit Select residential natural gas heaters Variable ratings across boutique online suppliers

A high-quality replacement thermopile must reach a flame temperature of approximately 1202 degrees Fahrenheit to reliably generate its rated 750 millivolts. If an aftermarket part fails to generate sufficient voltage, the gas control valve will continuously shut off the pilot gas supply as a safety precaution.

Finding official Whirlpool parts and support documents

When maintaining your water heater, relying on accurate schematics prevents ordering incompatible components. Exploded diagrams show how the burner manifold door gasket, pilot tube, and burner tube integrate inside the combustion chamber.

You can view official technical literature and diagrams through the Whirlpool owner center and water heater support portal. Before securing any replacement hardware:

  1. Verify the complete model number from the tank data plate.
  2. Confirm your fuel source is natural gas, never liquid propane.
  3. Check the condition of the burner door gasket, as an unsealed combustion chamber violates FVIR safety standards.

Installation Requirements and Safety Checks

Combustion air, venting, and gas connections

Installing or servicing a natural gas water heater requires strict adherence to the National Fuel Gas Code (NFPA 54 / ANSI Z223.1) and local municipal plumbing regulations. Because the 40T6-34NG utilizes atmospheric Category I natural-draft venting, proper airflow is critical to prevent dangerous backdrafting and carbon monoxide accumulation.

Combustion air and venting layout workflow

Combustion air supply must be calculated based on the total BTU input of all fuel-burning appliances located in the same room. For an unconfined space, the standard guideline requires at least 50 cubic feet of room volume per 1,000 BTU per hour of combined appliance input. If your water heater (34,000 BTU per hour) shares a utility space with a 100,000 BTU per hour furnace, the total input is 134,000 BTU per hour, requiring 6,700 cubic feet of interior volume.

When modern home construction seals interior air tightly, outside combustion air openings must be installed:

  • Two permanent openings communicating with outdoor air: one within 12 inches of the ceiling and one within 12 inches of the floor.
  • Each opening must provide a minimum free area of 100 square inches, taking into account the airflow restriction of louvers or grilles.

Venting must connect to an approved chimney or UL-listed Type B double-wall vent pipe. The vent connector requires a minimum 12-inch vertical rise directly off the draft hood before introducing any elbow or horizontal offset. Horizontal runs must maintain an upward pitch of at least 1/4 inch per foot toward the vent terminal.

For the gas supply line, codes mandate:

  • A dedicated manual shutoff valve installed upstream of the heater.
  • A sediment trap (drip leg) measuring at least 3 inches in length installed before the gas control inlet.
  • A ground joint union to permit servicing.
  • Thorough leak testing of all joints using an approved non-corrosive gas leak detection solution or a mixture of one part dish soap to 15 parts water. Never use open flames to check for leaks.

Operating safeguards and when to call a professional

Atmospheric gas water heaters contain several interlocking safety systems designed to prevent hazardous operating conditions:

  • FVIR Flame Arrestor: Located at the base of the burner chamber, this component prevents external flammable vapors from flashing back into the surrounding room. Keep the base filter clean and free of lint, dust, and pet hair.
  • T&P Relief Valve: Protects the vessel from over-pressurization. The discharge line must be piped downward to within 6 inches of the floor or into an approved drain pan, pitched to prevent water collection.
  • Closed Loop Thermal Expansion: If your home plumbing features a backflow preventer or pressure-reducing valve, water heating creates thermal expansion that can elevate household pressure beyond safe thresholds (above 80 psi). A dedicated thermal expansion tank installed on the cold line protects the heater tank from premature rupture.

Working with fuel gas lines, combustion chambers, and exhaust venting carries inherent safety risks. If you experience persistent pilot outages, smell fuel gas, notice soot around the draft hood, or observe an error code on the electronic control, do not attempt to bypass safety sensors. Engaging a licensed professional ensures your water heating equipment operates efficiently and complies fully with local safety codes.

Frequently Asked Questions About 40t6 34ng 400

Is 40T6-34NG-400 the same heater as 40T6-34NG?

Yes. The 40T6-34NG is the primary base model number, while 40T6-34NG-400 represents the full engineering and retail parts catalog number. Both refer to the identical 40-gallon tall natural gas unit with UPC 035505155450.

Can this 40-gallon model operate at high altitude?

Yes. The 40T6-34NG series is factory-certified for standard operation at elevations ranging from 0 to 10,100 feet without requiring specialized high-altitude conversion kits for standard installations.

Does 100112330 replace 9007876 and 9007877?

Yes. Part number 100112330 is the direct factory-approved replacement for superseded numbers 9007876 and 9007877. It includes the complete natural gas pilot tube, bracket, spark igniter wire, and 750-millivolt thermopile.

Conclusion

Understanding what the 40T6-34NG-400 designation means allows you to make informed decisions regarding water heater repairs and replacements. Always verify the data rating plate on your tank, cross-reference compatible part numbers like 100112330 for pilot assemblies, and confirm that your home venting and gas supply meet current standards.

When dealing with gas controls, combustion safety, or full unit replacements, professional service ensures lasting performance and peace of mind. Plumbing Tech LLC provides experienced, certified plumbing solutions across Greater Cleveland, OH, including Strongsville and Richfield. Whether you need diagnostics, component replacements, or comprehensive water heater repair and installation service, our team delivers skilled workmanship backed by a 100% satisfaction guarantee.

Get Help Now

Consent